[UPDATED 2023] Getting HPE0-S59 Certification Made Easy! [Q32-Q56]

Share

[UPDATED 2023] Getting HPE0-S59 Certification Made Easy!

HPE0-S59 Exam Crack Test Engine Dumps Training With 60 Questions

NEW QUESTION # 32
Which statement about an HPE Oneview support dump is true?

  • A. Support dump is a binary file that can be opened only in a dedicated application
  • B. Support dump can be created if HPE Virtual Connect modules are installed in the frame
  • C. Appliance support dump by default contains a logical enclosure support dump
  • D. Preview support dump is available only when creating an appliance support dump

Answer: A


NEW QUESTION # 33
Which compute node parameters are captured within server hardware type?

  • A. installed operating system
  • B. Mezzanine card configuration
  • C. Number of the CPUs
  • D. Size of the memory Installed

Answer: A


NEW QUESTION # 34
Match each HPE OneView network type with its definition.

Answer:

Explanation:


NEW QUESTION # 35
You modified a logical interconnect group mat is used to configure logical interconnects in five different logical enclosures. What will be the impact of that change?

  • A. All physical interconnects from affected logical interconnects will be placed in a maintenance mode
  • B. All physical interconnects from the affected logical interconnects must he rebooted to activate the new configuration
  • C. All logical interconnects configured using this logical Interconnect group will report inconsistency
  • D. All logical interconnects configured using this logical interconnect group will be automatically updated

Answer: A


NEW QUESTION # 36
Which statement about HPE Apollo 2000 Gen10 Plus platform is true?

  • A. It offers servers with AMD EPYC and Intel Xeon Scalable CPUs
  • B. It is equipped with HPE Persistent memory by default
  • C. It is fully managed using HPE OneView including all connections
  • D. It can support a single processor only and up to 4 per chassis

Answer: D


NEW QUESTION # 37
You need to configure a RoCE network to enable lossless networking for HPE J2000 Flash Enclosure support Which interconnects are required to support this connection? (Select two.)

  • A. Brocade 32Gb Fibre Channel SAN Switch Module for HPE Synergy
  • B. Brocade 16Gb Fibfe Channel SAN Switch Module for HPE Synergy
  • C. HPE Virtual Connect SE 16Gb FC Module for HPE Synergy
  • D. HPE Virtual Connect SE 40Gb F8 Module for HPE Synergy
  • E. HPE Virtual Connect SE 100Gb F32 Module for HPE Synergy
  • F. HPE Virtual Connect SE 32Gb FC Module for HPE Synergy

Answer: C,F


NEW QUESTION # 38
Your customer wants to add a second HPE Synergy frame to an existing logical enclosure Based on a single HPE Synergy frame. The customer wants to use a highly available master setup.
Which procedures should De performed during the expansion process? (Select two.)

  • A. Move one of the master modules to the appropriate interconnect bay in the second frame.
  • B. Modify an existing logical interconnect to include second HPE Synergy frame.
  • C. Create a new logical enclosure based on both HPE Synergy frames.
  • D. Re-parent an existing enclosure group to the new logical interconnect group.
  • E. Create a new logical interconnect group and enclosure group for two frames setup

Answer: B,C


NEW QUESTION # 39
Your customer has 6 logical enclosures spanning 18 HPE Synergy frames. The customer needs to add one more logical enclosure based on 5 HPE Synergy frames How will this change impact the customer environment?

  • A. The customer can add a new logical enclosure to an existing setup once all required licenses are added lo HPE OneView and associated with the new frames.
  • B. The customer has to create a new management ring for new logical enclosure because the maximum number of frames m a single management ring is reached.
  • C. The customer has to expand the management ring capacity either by adding HPE Composer 2 modules or adding memory to reach 128GB per module.
  • D. The customer can add a new logical enclosure to the existing setup because the maximum number of logical enclosures in a single management ring is not reached.

Answer: D


NEW QUESTION # 40
Your customer reports mat an external FC boot volume for Windows server is visible four times in the Disk Management 1 online and 3 offline.
What should you do to resolve this issue?

  • A. Install and configure MPIO on me Windows system
  • B. Remove the offline disks using Windows Disk Management
  • C. Remove the offline disks using array management tools
  • D. Disable deduplication for this volume at the array level

Answer: A


NEW QUESTION # 41
Your customer plans to use HPE Primera to boot HPE Synergy compute nodes. They currently have two HPE Virtual Connect SE 100Gb F32 Module for Synergy modules installed in the frame. The customer wants to use FC as a storage access protocol What must be done to complete this task?

  • A. Enable FC primary and secondary boot on the modules through the HPE OneView interface
  • B. Add FC upgrade licenses in HPE OneView that will enable FC connectivity for the modules
  • C. FC connectivity on the modules should be enabled through the service console by disabling FCoE.
  • D. Enter both modules into a maintenance mode, then enable FC connectivity through CLI

Answer: C


NEW QUESTION # 42
Refer to the exhibit.

Which statement about this logical JBOD is true?

  • A. After deleting this logical JBOD, its drives w not be available until a clean-up procedure 6 done
  • B. After deleting this logical JBOD drives will he blocked for 12h m case this JBOD must be re-created
  • C. This logical JBOD can be connected to multiple systems to formulate a snared datastore.
  • D. This logical JBOD can be presented to the compute nodes in a different frame.

Answer: A


NEW QUESTION # 43
Your customer is implementing an HPE Synergy solution based on three frames.
Click each of the ports that can be used to connect satellite modules.

Answer:

Explanation:


NEW QUESTION # 44
Your customer needs to move an application from an HPE Synergy 480 Gen10 Compute Module to an HPE Synergy 660 Gen 10 Compute Module. The 480 has a switch that has been manually zoned outside of HPE OneView.
What must the customer do before migrating the application?

  • A. Migrate the application to a Logical JBOD and connect it to the new server
  • B. Copy the server profile and assign the clone to the new hardware
  • C. Create a new server profile template and apply to the new hardware
  • D. Edit the server profile and change server hardware type

Answer: D


NEW QUESTION # 45
Your customer has an HPE Synergy frame equipped with a D3940 Storage Module. Each of the compute nodes has an appropriate storage controller Installed and two 12Gb SAS switches installed in the first fabric.
The customer reports that compute nodes cannot access the storage module. What should you verify first when troubleshooting this problem?

  • A. If there Is a logical interconnect created based on the 12Gb SAS switches.
  • B. If there is at least one ISCSI network configured that will provide access to the module.
  • C. If the D3940 module is imported in managed state that allows volume provisioning.
  • D. If the D3940 storage module is property licensed through HPE OneView interface.

Answer: C


NEW QUESTION # 46
Click the drop-down menu that will allow you to define the location of the master modules within the logical interconnect group.

Answer:

Explanation:


NEW QUESTION # 47
Your customer reports that they cannot deploy HPE Synergy compute nodes using HPE OneView for VMware vCenter Server (HPE OV4VC).
What should you check during troubleshooting process?

  • A. If the HPE Oneview instance Is integrated with HPE OV4VC.
  • B. If HPE OneView credentials are added in vCenter Server
  • C. If vCenter Server is licensed in the HPE Oneview interface
  • D. If an compute nodes are added to the vCenter Server

Answer: D


NEW QUESTION # 48
You plan to configure a Link Aggregation Group (LAG) for two connections within a server profile for a compute node running an ESXI system.
What is required from the VMware side to enable LAG?

  • A. Load balancing cluster
  • B. Dedicated VMKernel port
  • C. vSphere Standard license
  • D. Virtual Distributed Switch

Answer: B


NEW QUESTION # 49
Your customer plans to deploy VMware ESXi 7. 0 U2, and they are looking for a hardware platform that will allow them to use up to 16 CPU sockets Which HPE compute system meets the customer requirements?

  • A. HPE Synergy 480 Gen10 Plus
  • B. HPE ProLiant DL580 Gen10
  • C. HPE Superdome Flex system
  • D. HPE ProLiant OL380 Gen 10 Plus

Answer: A


NEW QUESTION # 50
Click the area within the iLO management interface that will allow you to access workload Advisor.

Answer:

Explanation:


NEW QUESTION # 51
What is a limitation when creating a server profile?

  • A. It is not possible to create shared volumes on demand through a server profile
  • B. ILO management is limited to the integration with Active Directory or LDAP
  • C. BIOS settings can be changed only when UEFI optimized is selected as boot mode
  • D. Administrator cannot define more than 8 connections within a server profile

Answer: B


NEW QUESTION # 52
Which statement about HPE Superdome Flex 280 is true?

  • A. it cannot be managed using HPE OneView.
  • B. It must be equipped with at least 768 GB of memory.
  • C. It supports 2 to 8 sockets in 2-socket increments.
  • D. It can support up to two nPars with an external RMC.

Answer: B


NEW QUESTION # 53
Which statement about a new HPE SimpliVity deployment is true?

  • A. All new HPE SimpliVity models are based on AMD CPUs
  • B. New HPE SimpliVity deployments are licensed per node not per physical socket
  • C. New HPE SimpliVity deployments give customer flexible choice of hypervisor
  • D. All new HPE SimpliVity models support deduplication and compression

Answer: D


NEW QUESTION # 54
Your customer plans to deploy VMware ESXi 7 0 U2 and they are looking for a hardware platform mat wilt allow them to use up to 24 TB of physical memory.
Which HPE compute system meets this customer's requirements?

  • A. HPE ProLiant DL380 Gen 10 Plus
  • B. HPE ProLiant DL560 Gen10
  • C. HPE Synergy 480 Gen10 Plus
  • D. HPE Superdome Flex 280

Answer: A


NEW QUESTION # 55
What is a restriction of using a RoCE network?

  • A. It is by default configured as an untagged network and cannot be a part of a network set.
  • B. it is not supported with HPE Virtual Connect SE 40 GD F8 Module for HPE Synergy.
  • C. It does not support smart link and private network features.
  • D. It does not support Private VLAN and Multicast VLAN.

Answer: A


NEW QUESTION # 56
......

HPE0-S59 Exam Dumps Contains FREE Real Quesions from the Actual Exam: https://www.dumpsreview.com/HPE0-S59-exam-dumps-review.html

Obtain the HPE0-S59 PDF Dumps Get 100% Outcomes Exam Questions For You To Pass: https://drive.google.com/open?id=1JZTh8g7VDFwBJCe1ki2sUQ0GmdFK10jz